Solid Edge St2 Software Development
Legal Notices-----©2010 Siemens Product Lifecycle Management Software Inc. Solid Edge ST8 SDK. Solid Edge ST2 MP2 - Readme. Solid Edge aborts after.
Here are some answers to questions that might come up as you're thinking of registering. What do I get for my registration Fee? There are 2 main registration Schemes providing the following benefits. Standard registration gives access to all of our Building Regs Specifications for a full year. Premium registration provides access to both our Building Regs Specifications and our Detail Drawings, for a full year. I haven't heard of the site before.
Is it reliable, reputable? Will I get what I pay for?
Thousands of very satisfied users have registered over the six years during which the site has been running. Most of our users praise the service as very beneficial, helpful and reliable. Plus, very good value.
Some our our users' reviews are available on How do I sign up and what is the cost? You can sign-up on our Prices are shown on the registration page.
How do I pay? Payment can be made by Paypal or by Credit/Debit Card. Credit/Debit Card payments are accepted via Paypal, without the need for a Paypal account. We also accept direct BACS/online payments direct to our bank account. Please contact us for details. Specifications for Home Extension, New Build, Flat Conversion, Loft & Garage Conversion, New Build Flats and Garage Build Plans The Construction Notes & Specifications form an essential component of a Building Regulations plans submission for Building Control or for an Approved Inspector.
Building Regulations Guidance Notes and Approved Documents are an aid to compiling Construction Notes for drawings but preparing a clear and concise specification for an Application can prove to be an arduous task. This is where our innovative and easy-to-use App for producing Building Regulations Specifications for Home Extension, Loft, Flat and Garage Conversion, Garage Build and New Build Plans comes into its own, offering more than standard construction guidance.
Here's a screenshot of the Building Regulations Specification App (for house extensions): Our categorised pre-prepared Building Regulations Construction Notes can be added within the App with a few clicks of the mouse into a specification that is custom-designed to meet the requirements of your Building Project. Many of our construction notes are very specific, so please select the correct one for your situation (ie correct dimensions, type of insulation) and type of plans (ie house extensions, loft, flat, garage conversions or garage builds), eg To meet min U value required of 0.22 W/m²K Solid ground floor to consist of 150mm consolidated well rammed hardcore. Blinded with 50mm sand blinding. Provide 100mm ST2 or Gen1 reinforced concrete ground bearing slab under a 1200mm gauge polythene dpm or 3 coats RIW. Dpm to be lapped in with dpc in walls. Floor to be insulated over slab and dpm with min 75m thick Celotex GA4000, 25mm Celotex insulation to continue around floor perimeters to avoid thermal bridging. A vcl should be laid over the Celotex insulation boards and turned up 100mm at room perimeters behind the skirting, all joints to be lapped 150mm and sealed.
Finish with 65mm sand/cement finishing screed with light mesh reinforcement. Where drain runs pass under new floor provide A142 mesh 1.0m wide and min 50mm concrete cover over length of drain.
Where existing suspended timber floor air bricks are covered by new extension, ensure cross ventilation is maintained by connecting to 100mm dia upvc pipes with 100mm concrete cover laid under the extension. Pipes to terminate at new 65mm x 215mm air bricks with cavity tray over. However, the site makes it easy to choose your specification. The note above would be found by navigating through the App in the section:. Ground Floors Solid Floor Insulation Over Slab Screed Finish 75mm Celotex Concise Notes like these shown above, can be added to your house extension specification with just a few clicks in our app!
(You can also add the associated construction detail drawing to your basket.) Another example (from House Extensions): WARM PITCHED ROOF UNVENTED Pitch 22-45° (imposed load max 0.75 kN/m² - dead load max 0.75 kN/m²)To achieve min U-value required of 0.18 W/m²K Roofing tiles to match existing fixed to tile battens secured over breathable sarking felt to BS747 or relevant BBA Certificate allowing the breather felt to sag at least 10mm over preservative treated counter battens (min 38mm x 50mm). Provide 110mm Celotex FR4000 insulation boards installed under the counter battens and over 47 x 100mm timber rafters (strength class C24 at 400 c/c – to give a max 2.58m span). A vapour control layer should be provided to the underside of the rafters. Finish with 12.5 plasterboard and skim. Restraint strapping - Ceiling joists tied to rafters (if raised collar roof consult structural engineer) and 100mm x 50mm wall plate strapped down to walls across at least 3 timbers using 1000 x 30 x 5mm galvanized straps or other approved to BSEN 845-1 and appropriate noggins at 1.2m centres built into cavity in accordance with CP111 Part 2.
Gable walls to be strapped to rafters using galvanized steel built into cavity strapping at 2m ctrs and fixed over 3 rafters with noggins. Other Building Regulations Construction Notes in our app are supplied with just a single version such as (from House Extension, Loft and Garage Conversions): ELECTRICAL All electrical work required to meet the requirements of Part P (electrical safety) must be designed, installed, inspected and tested by a competent person registered under a competent person self certification scheme such as BRE certification Ltd, BSI, NICEIC Certification Services or Zurich Ltd. An appropriate BS7671 Electrical Installation Certificate is to be issued for the work by a person competent to do so. A copy of a certificate will be given to the Council. And (from House Extensions) LEAD WORK AND FLASHINGS All lead flashings, any valleys or soakers to be Code 5 lead and laid according to Lead Development Association. Flashings to be provided to all jambs and below window openings with welded upstands.
Joints to be lapped min 150mm and lead to be dressed 200mm under tiles, etc. All work to be undertaken in accordance with the Lead Development Association recommendations.
The note above can be found. Roofs Lead Work To tryout our Building Regulations Specification App, you can begin straightaway by clicking one of the main category buttons above,,,,,. To access the Loft Conversion, Garage Conversion, Flat Conversion, New Build or Garage Build Specifications you'll need to register for an account. But you can see our House Extension specifications on the app (although the 'copy' function has been disabled for non-registered users.) If you want some help and guidance before getting started please look at our or watch the 3-minute. There are also information pages that you should read for and as well as an page.
Or, you can uninstall Solid Edge 2D Drafting ST2 from your computer by using the Add/Remove Program feature in the Window's Control Panel. • On the Start menu (for Windows 8, right-click the screen's bottom-left corner), click Control Panel, and then, under Programs, do one of the following: • Windows Vista/7/8: Click Uninstall a Program. • Windows XP: Click Add or Remove Programs. • When you find the program Solid Edge 2D Drafting ST2, click it, and then do one of the following: • Windows Vista/7/8: Click Uninstall. • Windows XP: Click the Remove or Change/Remove tab (to the right of the program).
• Follow the prompts. A progress bar shows you how long it will take to remove Solid Edge 2D Drafting ST2.
UpdateStar is compatible with Windows platforms. UpdateStar has been tested to meet all of the technical requirements to be compatible with Windows 10, 8.1, Windows 8, Windows 7, Windows Vista, Windows Server 2003, 2008, and Windows XP, 32 bit and 64 bit editions. The Great Debaters Ita Adobe Illustrator here. Simply double-click the downloaded file to install it. UpdateStar Free and UpdateStar Premium come with the same installer. UpdateStar includes such as English, German, French, Italian, Hungarian, Russian and. You can choose your language settings from within the program.